1.
J Med Ultrasound ; 32(1): 32-40, 2024.
Article in English | MEDLINE | ID: mdl-38665339

ABSTRACT

Background: Noninvasive neurosurgery has become possible through the use of transcranial focused ultrasound (FUS). This study assessed the heating ability of single element spherically focused transducers operating at 0.4 and 1.1 MHz through three-dimensional (3D) printed thermoplastic skull phantoms. Methods: Phantoms with precise skull bone geometry of a male patient were 3D printed using common thermoplastic materials following segmentation on a computed tomography head scan image. The brain tissue was mimicked by an agar-based gel phantom developed in-house. The selection of phantom materials was mainly based on transmission-through attenuation measurements. Phantom sonications were performed through water, and then, with the skull phantoms intervening the beam path. In each case, thermometry was performed at the focal spot using thermocouples. Results: The focal temperature change in the presence of the skull phantoms was reduced to less than 20 % of that recorded in free field when using the 0.4 MHz transducer, whereas the 1.1 MHz trans-skull sonication produced minimal or no change in focal temperature. The 0.4 MHz transducer showed better performance in trans-skull transmission but still not efficient. Conclusion: The inability of both tested single element transducers to steer the beam through the high attenuating skull phantoms and raise the temperature at the focus was confirmed, underlying the necessity to use a correction technique to compensate for energy losses, such those provided by phased arrays. The proposed phantom could be used as a cost-effective and ergonomic tool for trans-skull FUS preclinical studies.

2.
medRxiv ; 2024 Feb 13.
Article in English | MEDLINE | ID: mdl-38405768

ABSTRACT

Bipolar disorder (BD) is a heritable mental illness with complex etiology. While the largest published genome-wide association study identified 64 BD risk loci, the causal SNPs and genes within these loci remain unknown. We applied a suite of statistical and functional fine-mapping methods to these loci, and prioritized 22 likely causal SNPs for BD. We mapped these SNPs to genes, and investigated their likely functional consequences by integrating variant annotations, brain cell-type epigenomic annotations, brain quantitative trait loci, and results from rare variant exome sequencing in BD. Convergent lines of evidence supported the roles of SCN2A, TRANK1, DCLK3, INSYN2B, SYNE1, THSD7A, CACNA1B, TUBBP5, PLCB3, PRDX5, KCNK4, AP001453.3, TRPT1, FKBP2, DNAJC4, RASGRP1, FURIN, FES, YWHAE, DPH1, GSDMB, MED24, THRA, EEF1A2, and KCNQ2 in BD. These represent promising candidates for functional experiments to understand biological mechanisms and therapeutic potential. Additionally, we demonstrated that fine-mapping effect sizes can improve performance and transferability of BD polygenic risk scores across ancestrally diverse populations, and present a high-throughput fine-mapping pipeline (https://github.com/mkoromina/SAFFARI).

3.
Phys Med ; 117: 103194, 2024 Jan.
Article in English | MEDLINE | ID: mdl-38048730

ABSTRACT

PURPOSE: The study aimed to compare the performance of eight commercially available single-element High Intensity Focused Ultrasound (HIFU) transducers in terms of Magnetic Resonance Imaging (MRI) compatibility. METHODS: Imaging of an agar-based MRI phantom was performed in a 3 T MRI scanner utilizing T2-Weighted Fast Spin Echo (FSE) and Fast low angle shot (FLASH) sequences, which are typically employed for high resolution anatomical imaging and thermometry, respectively. Reference magnitude and phase images of the phantom were compared with images acquired in the presence of each transducer in terms of the signal to noise ratio (SNR), introduced artifacts, and overall image quality. RESULTS: The degree of observed artifacts highly differed among the various transducers. The transducer whose backing material included magnetic impurities showed poor performance in the MRI, introducing significant susceptibility artifacts such as geometric distortions and signal void bands. Additionally, it caused the most significant SNR drop. Other transducers were shown to exhibit high level of MRI compatibility as the resulting images closely resembled the reference images with minimal to no apparent artifacts and comparable SNR values. CONCLUSIONS: The study findings may facilitate researchers to select the most suitable transducer for their research, simultaneously avoiding unnecessary testing. The study further provides useful design considerations for MRI compatible transducers.


Subject(s)
Magnetic Resonance Imaging , Transducers , Magnetic Resonance Imaging/methods , Signal-To-Noise Ratio , Phantoms, Imaging , Artifacts
4.
J Ultrasound ; 2023 Jul 29.
Article in English | MEDLINE | ID: mdl-37516718

ABSTRACT

PURPOSE: Amyloid-ß (Aß) peptides, the main component of amyloid plaques found in the Alzheimer's disease (AD) brain, are implicated in its pathogenesis, and are considered a key target in AD therapeutics. We herein propose a reliable strategy for non-invasively delivering a specific anti-Aß antibody in a mouse model of AD by microbubbles-enhanced Focused Ultrasound (FUS)-mediated Blood-brain barrier disruption (BBBD), using a simple single stage MR-compatible positioning device. METHODS: The initial experimental work involved wild-type mice and was devoted to selecting the sonication protocol for efficient and safe BBBD. Pulsed FUS was applied using a single-element FUS transducer of 1 MHz (80 mm radius of curvature and 50 mm diameter). The success and extent of BBBD were assessed by Evans Blue extravasation and brain damage by hematoxylin and eosin staining. 5XFAD mice were divided into different subgroups; control (n = 1), FUS + MBs alone (n = 5), antibody alone (n = 5), and FUS + antibody combined (n = 10). The changes in antibody deposition among groups were determined by immunohistochemistry. RESULTS: It was confirmed that the antibody could not normally enter the brain parenchyma. A single treatment with MBs-enhanced pulsed FUS using the optimized protocol (1 MHz, 0.5 MPa in-situ pressure, 10 ms bursts, 1% duty factor, 100 s duration) transiently disrupted the BBB allowing for non-invasive antibody delivery to amyloid plaques within the sonicated brain regions. This was consistently reproduced in ten mice. CONCLUSION: These preliminary findings should be confirmed by longer-term studies examining the antibody effects on plaque clearance and cognitive benefit to hold promise for developing disease-modifying anti-Aß therapeutics for clinical use.

5.
J Ultrasound ; 2023 Jul 30.
Article in English | MEDLINE | ID: mdl-37517052

ABSTRACT

PURPOSE: The study aims to provide insights on the practicality of using single-element transducers for transcranial Focused Ultrasound (tFUS) thermal applications. METHODS: FUS sonications were performed through skull phantoms embedding agar-based tissue mimicking gels using a 1 MHz single-element spherically focused transducer. The skull phantoms were 3D printed with Acrylonitrile Butadiene Styrene (ABS) and Resin thermoplastics having the exact skull bone geometry of a healthy volunteer. The temperature field distribution during and after heating was monitored in a 3 T Magnetic Resonance Imaging (MRI) scanner using MR thermometry. The effect of the skull's thickness on intracranial heating was investigated. RESULTS: A single FUS sonication at focal acoustic intensities close to 1580 W/cm2 for 60 s in free field heated up the agar phantom to ablative temperatures reaching about 90 °C (baseline of 37 °C). The ABS skull strongly blocked the ultrasonic waves, resulting in zero temperature increase within the phantom. Considerable heating was achieved through the Resin skull, but it remained at hyperthermia levels. Conversely, tFUS through a 1 mm Resin skull showed enhanced ultrasonic penetration and heating, with the focal temperature reaching 70 °C. CONCLUSIONS: The ABS skull demonstrated poorer performance in terms of tFUS compared to the Resin skull owing to its higher ultrasonic attenuation and porosity. The thin Resin phantom of 1 mm thickness provided an efficient acoustic window for delivering tFUS and heating up deep phantom areas. The results of such studies could be particularly useful for accelerating the establishment of a wider range of tFUS applications.

6.
Int J Med Robot ; 19(5): e2526, 2023 Oct.
Article in English | MEDLINE | ID: mdl-37165718

ABSTRACT

BACKGROUND: The current study proposes simple methods for assessing the performance of robotic devices intended for Magnetic Resonance Imaging (MRI)-guided needle biopsy. METHODS: In-house made agar-based breast phantoms containing biopsy targets served as the main tool in the evaluation process of an MRI compatible positioning device comprising a needle navigator. The motion accuracy of mechanical stages was assessed by calliper measurements. Laboratory evaluation of needle targeting included a repeatability phantom test and a laser-based method. The accuracy and repeatability of needle targeting was also assessed by MRI. RESULTS: The maximum error of linear motion for steps up to 10 mm was 0.1 mm. Needle navigation relative to the phantom and alignment with the various biopsy targets were performed successfully in both the laboratory and MRI settings. The proposed biopsy phantoms offered tissue-like signal in MRI and good haptic feedback during needle insertion. CONCLUSIONS: The proposed methods could be valuable in the process of validating the accuracy of MRI-guided biopsy robotic devices in both laboratory and real environments.


Subject(s)
Robotic Surgical Procedures , Humans , Image-Guided Biopsy , Needles , Phantoms, Imaging , Magnetic Resonance Imaging/methods , Biopsy, Needle
7.
Med Phys ; 50(10): 5956-5968, 2023 Oct.
Article in English | MEDLINE | ID: mdl-37226334

ABSTRACT

BACKGROUND: The persistent development of focused ultrasound (FUS) thermal therapy in the context of oncology creates the need for tissue-mimicking tumor phantom models for early-stage experimentation and evaluation of relevant systems and protocols. PURPOSE: This study presents the development and evaluation of a tumor-bearing tissue phantom model for testing magnetic resonance imaging (MRI)-guided FUS (MRgFUS) ablation protocols and equipment based on MR thermometry. METHODS: Normal tissue was mimicked by a pure agar gel, while the tumor simulator was differentiated from the surrounding material by including silicon dioxide. The phantom was characterized in terms of acoustic, thermal, and MRI properties. US, MRI, and computed tomography (CT) images of the phantom were acquired to assess the contrast between the two compartments. The phantom's response to thermal heating was investigated by performing high power sonications with a 2.4 MHz single element spherically focused ultrasonic transducer in a 3T MRI scanner. RESULTS: The estimated phantom properties fall within the range of literature-reported values of soft tissues. The inclusion of silicon dioxide in the tumor material offered excellent tumor visualization in US, MRI, and CT. MR thermometry revealed temperature elevations in the phantom to ablation levels and clear evidence of larger heat accumulation within the tumor owing to the inclusion of silicon dioxide. CONCLUSION: Overall, the study findings suggest that the proposed tumor phantom model constitutes a simple and inexpensive tool for preclinical MRgFUS ablation studies, and potentially other image-guided thermal ablation applications upon minimal modifications.


Subject(s)
High-Intensity Focused Ultrasound Ablation , Neoplasms , Humans , High-Intensity Focused Ultrasound Ablation/methods , Neoplasms/diagnostic imaging , Neoplasms/surgery , Magnetic Resonance Imaging , Phantoms, Imaging , Silicon Dioxide
8.
Medicina (Kaunas) ; 59(4)2023 Apr 09.
Article in English | MEDLINE | ID: mdl-37109692

ABSTRACT

Background and objectives: Migraine is considered the most clinically important primary headache due to its high prevalence and significant burden. Although globally categorized as one of the leading causes of disability, it is still largely underdiagnosed and undertreated. Worldwide, migraine care is in most cases provided by primary care physicians. The aim of our study was to assess the attitudes of Greek primary care physicians toward treating migraine compared to other common neurological and general medical disorders. Methods: We surveyed 182 primary care physicians with the use of a 5-point questionnaire regarding their preference in treating ten common medical conditions, including migraine, hypertension, hyperlipidemia, upper respiratory tract infections, diabetes mellitus, lower back pain, dizziness, transient ischemic attack, diabetic peripheral neuropathy, and fibromyalgia. Results: Overall, with regards to preference to treat, migraine scored very low (3.6 ± 1.0), next to diabetic peripheral neuropathy (3.6 ± 1.0), and third from the bottom to fibromyalgia (3.25 ± 1.06). In contrast, physicians reported a much higher preference to treat hypertension (4.66 ± 0.60) and hyperlipidemia (4.6 ± 1.0). Conclusions: Our results indicate that Greek primary care physicians dislike treating migraines but also other neurological diseases. Topics for further investigation include the reasons for this dislike, any associations with poor patient satisfaction, treatment results, or both.


Subject(s)
Diabetic Neuropathies , Fibromyalgia , Hypertension , Migraine Disorders , Physicians, Primary Care , Humans , Greece , Migraine Disorders/therapy , Surveys and Questionnaires , Hypertension/therapy
9.
Ultrasonics ; 132: 106974, 2023 Jul.
Article in English | MEDLINE | ID: mdl-36917874

ABSTRACT

In recent years, veterinary medicine has expanded its practices beyond conventional methods, gradually integrating the Focused Ultrasound (FUS) technology in the care of companion animals like dogs and cats. The current study aimed to examine the feasibility and provide insights into the application of thermal FUS in canine and feline mammary cancer therapy. FUS was delivered by a 2-MHz single-element spherically focused ultrasonic transducer as integrated with an existing robotic positioning device. The functionality of the FUS system and sonication protocol in efficiently and safely ablating live tissue was initially validated in a rabbit thigh model in a laboratory environment. Nine (9) dogs and cats with superficial mammary cancer were recruited through a dedicated campaign according to specific safety criteria. The veterinary patients underwent FUS ablation followed by immediate surgical resection of the entire malignancy. Histopathology examination demonstrated well-defined regions of coagulative necrosis in all treated tumors with no off-target damage. Further study with a larger patient population is needed to confirm the current findings and demonstrate the safety and feasibility of complete FUS ablation of deep-seated tumors.


Subject(s)
Breast Neoplasms , Cat Diseases , Dog Diseases , Ultrasonic Therapy , Cats , Animals , Dogs , Humans , Rabbits , Female , Pilot Projects , Cat Diseases/diagnostic imaging , Cat Diseases/surgery , Ultrasonic Therapy/methods
10.
Ultrasonics ; 131: 106955, 2023 May.
Article in English | MEDLINE | ID: mdl-36854247

ABSTRACT

Tissue mimicking phantoms (TMPs) play an essential role in modern biomedical research as cost-effective quality assurance and training tools, simultaneously contributing to the reduction of animal use. Herein, we present the development and evaluation of an anatomically accurate mouse phantom intended for image-guided thermal ablation and Focused Ultrasound (FUS) applications. The proposed mouse model consists of skeletal and soft tissue mimics, whose design was based on the Computed tomography (CT) scans data of a live mouse. Advantageously, it is compatible with US, CT, and Magnetic Resonance Imaging (MRI). The compatibility assessment was focused on the radiological behavior of the phantom due to the lack of relevant literature. The X-ray linear attenuation coefficient of candidate materials was estimated to assess the one that matches best the radiological behavior of living tissues. The bone part was manufactured by Fused Deposition Modeling (FDM) printing using Acrylonitrile styrene acrylate (ASA) material. For the soft-tissue mimic, a special mold was 3D printed having a cavity with the unique shape of the mouse body and filled with an agar-based silica-doped gel. The mouse phantom accurately matched the size and reproduced the body surface of the imaged mouse. Tissue-equivalency in terms of X-ray attenuation was demonstrated for the agar-based soft-tissue mimic. The phantom demonstrated excellent MRI visibility of the skeletal and soft-tissue mimics. Good radiological contrast between the skeletal and soft-tissue models was also observed in the CT scans. The model was also able to reproduce realistic behavior during trans-skull sonication as proved by thermocouple measurements. Overall, the proposed phantom is inexpensive, ergonomic, and realistic. It could constitute a powerful tool for image-guided thermal ablation and FUS studies in terms of testing and optimizing the performance of relevant equipment and protocols. It also possess great potential for use in transcranial FUS applications, including the emerging topic of FUS-mediated blood brain barrier (BBB) disruption.


Subject(s)
Magnetic Resonance Imaging , Tomography, X-Ray Computed , Animals , Mice , Agar , Magnetic Resonance Imaging/methods , Phantoms, Imaging , Skull , Printing, Three-Dimensional
11.
Article in English | MEDLINE | ID: mdl-36634808

ABSTRACT

BACKGROUND: While predominant (PP) and onset polarity (OP) have considerable clinical and treatment implications in bipolar disorder (BD), the neurobiological underpinnings of PP and OP from a radiological perspective remain largely unknown. The main objective of this study is to investigate the neuroanatomical profile of polarity subphenotypes (PP and OP) in euthymic BD patients, using a standardized multimodal neuroimaging protocol to evaluate regional gray matter (GM) volumes, cortical thickness, as well as white matter (WM) integrity of major projection, commissural and association tracts. METHODS: Forty-two euthymic BD patients stratified for PP and OP and 42 healthy controls (HC) were included in this computational neuroimaging study to comprehensively characterize gray and white matter alterations. Univariate analyses of covariance (ANCOVAs) were conducted with Bonferroni corrections for each MRI modality and Cohen's d effect sizes were calculated for group comparisons. RESULTS: Phenotype-associated cortical thickness abnormalities and volumetric alterations were identified, but no WM changes ascertained. Specifically, we found a main effect of OP on GM volume of left middle frontal gyrus and of OP and PP (either or both) on cortical thickness of various regions previously implicated in BD, i.e. inferior frontal gyrus-pars opercularis (left) and pars orbitalis (bilateral), left lateral orbitofrontal gyrus, bilateral medial segment of the superior frontal gyrus, left planum polare, right anterior cingulate gyrus, left anterior and posterior insula, bilateral frontal operculum (both OP and PP); left anterior and posterior orbitofrontal gyrus, left transverse temporal gyrus, right posterior insula (only OP); and right medial frontal cortex (only PP). Based on the magnitude of differences on pairwise comparisons, we found a large effect of OP on cortical thickness in a single region (left anterior orbitofrontal gyrus) (OP-M > OP-D), while PP subgroups showed large or medium effect size differences in cortical thickness (PP-M > PP-D) in a wider array of regions (right medial frontal cortex, left frontal operculum, left inferior frontal gyrus-pars opercularis, bilateral medial segment of the superior frontal gyrus). For most regions, PP-D patients showed the greatest decreases in cortical thickness compared to HC while PP-M showed the smallest, with PP-U showing an "unspecified" pattern mostly lying in-between PP-D and PP-M. CONCLUSIONS: Our multimodal imaging findings suggest specific polarity BD subgroups with compromised cortical thickness; we recorded a greater impact of PP on brain structure compared to OP, which provides additional evidence that PP can be considered as a neurobiological specifier in BD.


Subject(s)
Bipolar Disorder , Humans , Bipolar Disorder/diagnostic imaging , Bipolar Disorder/genetics , Brain/diagnostic imaging , Cerebral Cortex , Prefrontal Cortex , Neuroimaging , Magnetic Resonance Imaging/methods
12.
J Ultrasound ; 26(2): 401-408, 2023 Jun.
Article in English | MEDLINE | ID: mdl-36329304

ABSTRACT

PURPOSE: The popularity of Magnetic Resonance guided Focused Ultrasound (MRgFUS) as a beneficial therapeutic solution for many diseases is increasing rapidly, thus raising the need for reliable quality assurance (QA) phantoms for routine testing of MRgFUS systems. In this study, we propose a thin acrylic film as the cheapest and most easily accessible phantom for assessing the functionality of MRgFUS hardware and software. METHODS: Through the paper, specific QA tests are detailed in the framework of evaluating an MRgFUS preclinical robotic device comprising a single element spherically focused transducer with a nominal frequency of 2.75 MHz. These tests take advantage of the reflection of ultrasonic waves at a plastic-air interface, which results in almost immediate lesion formation on the film at a threshold of applied acoustic energy. RESULTS: The phantom offered qualitative information on the power field distribution of the FUS transducer and the ability to visualize different FUS protocols. It also enabled quick and reliable assessment of various navigation algorithms as they are used in real treatments, and also allowed for the assessment of the accuracy of robotic motion. CONCLUSION: Therefore, it could serve as a useful tool for detecting defects in system's performance over its lifetime after establishing a baseline while concurrently contributing to establish QA and calibration guidelines for clinical routine controls.


Subject(s)
High-Intensity Focused Ultrasound Ablation , Surgery, Computer-Assisted , Humans , Magnetic Resonance Imaging/methods , Phantoms, Imaging , High-Intensity Focused Ultrasound Ablation/methods , Software
13.
Int J Med Robot ; 19(1): e2466, 2023 Feb.
Article in English | MEDLINE | ID: mdl-36169287

ABSTRACT

BACKGROUND: A robotic device featuring three motion axes was manufactured for preclinical research on focussed ultrasound (FUS). The device comprises a 2.75 MHz single element ultrasonic transducer and is guided by Magnetic Resonance Imaging (MRI). METHODS: The compatibility of the device with the MRI was evaluated by estimating the influence on the signal-to-noise ratio (SNR). The efficacy of the transducer in generating ablative temperatures was evaluated in phantoms and excised porcine tissue. RESULTS: System's activation in the MRI scanner reduced the SNR to an acceptable level without compromising the image quality. The transducer demonstrated efficient heating ability as proved by MR thermometry. Discrete and overlapping thermal lesions were inflicted in excised tissue. CONCLUSIONS: The FUS system was proven effective for FUS thermal applications in the MRI setting. It can thus be used for multiple preclinical applications of the emerging MRI-guided FUS technology. The device can be scaled-up for human use with minor modifications.


Subject(s)
Robotic Surgical Procedures , Swine , Humans , Animals , Robotic Surgical Procedures/methods , Ultrasonography , Magnetic Resonance Imaging/methods , Ultrasonics , Phantoms, Imaging
14.
Psychiatriki ; 2022 Nov 11.
Article in English | MEDLINE | ID: mdl-36436212

ABSTRACT

Type 2 diabetes mellitus (T2DM) is a common metabolic disorder with various medical and psychological adverse effects. Well-being in patients with T2DM is often compromised. The aim of the present study was to investigate clinicodemographic predictors of well-being in patients with T2DM with no known psychiatric history and explore the mediatory role of undiagnosed anxiety and depression. We recruited 175 outpatients with T2DM (54.3% males, aged 34-79 (mean 59.9) years) followed-up at the Diabetes Center of the General Hospital of Nikaia-Peiraeus in Athens. Patients included had no severe diabetes-related complications or known psychiatric history. Well-being was measured with the Mental Health Continuum Short-Form (MHC-SF), a novel 14-item tool measuring the emotional (EWB), social (SWB) and psychological (PWB) dimensions of well-being, as well as a total score of well-being (WBT). Hospital Anxiety and Depression Scale (HADS) was used for screening for undiagnosed anxiety (HADS-A) and depression (HADS-D). Patients' demographics, Body Mass Index (BMI), glycemic control (HbA1c), T2DM duration, comorbid hypertension or dyslipidemia and type of antidiabetic medication were investigated as predictors of well-being or its dimensions in stepwise linear regression models, also including or excluding HADS-A and HADS-D. Mediational effects of HADS-A and HADS-D were explored in structural equation models through path analyses. Results showed that 21.1% of participants had comorbid depression (HADS-D≥11) and 5.1% comorbid anxiety disorder (HADS-A≥11). In the models without HADS, higher WBT as well as EWB and PWB were significantly predicted by lower HbA1c (all p=0.001) and lower BMI (p=0.015, 0.019 and 0.030, respectively). After being included in the model, HADS-A and HADS-D significantly predicted WBT and every dimension of well-being, but the effects of HbA1c and BMI were no longer statistically significant. In path analyses, the indirect effects of HbA1c and BMI on well-being via HADS-D were statistically significant, while the direct and indirect effects via HADS-A were not. Therefore, the effects of HbA1c and BMI on EWB, PWB and WBT were completely mediated by HADS-D. Concludingly, this is the first study using MHC-SF to measure well-being in patients with T2DM. High levels of undiagnosed depression were recorded, in agreement with other studies. Depression was predicted by HbA1c and BMI and finally predicted well-being. Undiagnosed depression fully explained the effects of HbA1c and BMI on well-being. The interplay of glycemic control and positive mental health should be further investigated.

15.
J Magn Reson ; 344: 107317, 2022 11.
Article in English | MEDLINE | ID: mdl-36279604

ABSTRACT

Numerous challenges are faced when employing Magnetic Resonance guided Focused Ultrasound (MRgFUS) hardware in the Magnetic Resonance Imaging (MRI) setting. The current study aimed to provide insights on this topic through a series of experiments performed in the framework of evaluating the MRI compatibility of an MRgFUS robotic device. All experiments were performed in a 1.5 T MRI scanner. The main metric for MRI compatibility assessment was the signal to noise ratio (SNR). Measurements were carried out in a tissue mimicking phantom and freshly excised pork tissue under various activation states of the system. In the effort to minimize magnetic interference and image distortion, various set-up parameters were examined. Significant SNR degradation and image distortion occurred when the FUS transducer was activated mainly owing to FUS-induced target and coil vibrations and was getting worse as the output power was increased. Proper design and stable positioning of the imaged phantom play a critical role in reducing these vibrations. Moreover, isolation of the phantom from the imaging coil was proven essential for avoiding FUS-induced vibrations from being transferred to the coil during sonication and resulted in a more than 3-fold increase in SNR. The use of a multi-channel coil increased the SNR by up to 50 % compared to a single-channel coil. Placement of the electronics outside the coil detection area increased the SNR by about 65 %. A similar SNR improvement was observed when the encoders' counting pulses were deactivated. Overall, this study raises awareness about major challenges regarding operation of an MRgFUS system in the MRI environment and proposes simple measures that could mitigate the impact of noise sources so that the monitoring value of MR imaging in FUS applications is not compromised.


Subject(s)
Robotic Surgical Procedures , Magnetic Resonance Imaging/methods , Signal-To-Noise Ratio , Phantoms, Imaging , Transducers
16.
Ann Intern Med ; 175(11): 1560-1571, 2022 11.
Article in English | MEDLINE | ID: mdl-36252247

ABSTRACT

BACKGROUND: To what extent the COVID-19 pandemic and its containment measures influenced mental health in the general population is still unclear. PURPOSE: To assess the trajectory of mental health symptoms during the first year of the pandemic and examine dose-response relations with characteristics of the pandemic and its containment. DATA SOURCES: Relevant articles were identified from the living evidence database of the COVID-19 Open Access Project, which indexes COVID-19-related publications from MEDLINE via PubMed, Embase via Ovid, and PsycInfo. Preprint publications were not considered. STUDY SELECTION: Longitudinal studies that reported data on the general population's mental health using validated scales and that were published before 31 March 2021 were eligible. DATA EXTRACTION: An international crowd of 109 trained reviewers screened references and extracted study characteristics, participant characteristics, and symptom scores at each timepoint. Data were also included for the following country-specific variables: days since the first case of SARS-CoV-2 infection, the stringency of governmental containment measures, and the cumulative numbers of cases and deaths. DATA SYNTHESIS: In a total of 43 studies (331 628 participants), changes in symptoms of psychological distress, sleep disturbances, and mental well-being varied substantially across studies. On average, depression and anxiety symptoms worsened in the first 2 months of the pandemic (standardized mean difference at 60 days, -0.39 [95% credible interval, -0.76 to -0.03]); thereafter, the trajectories were heterogeneous. There was a linear association of worsening depression and anxiety with increasing numbers of reported cases of SARS-CoV-2 infection and increasing stringency in governmental measures. Gender, age, country, deprivation, inequalities, risk of bias, and study design did not modify these associations. LIMITATIONS: The certainty of the evidence was low because of the high risk of bias in included studies and the large amount of heterogeneity. Stringency measures and surges in cases were strongly correlated and changed over time. The observed associations should not be interpreted as causal relationships. CONCLUSION: Although an initial increase in average symptoms of depression and anxiety and an association between higher numbers of reported cases and more stringent measures were found, changes in mental health symptoms varied substantially across studies after the first 2 months of the pandemic. This suggests that different populations responded differently to the psychological stress generated by the pandemic and its containment measures. PRIMARY FUNDING SOURCE: Swiss National Science Foundation. (PROSPERO: CRD42020180049).


Subject(s)
COVID-19 , Humans , Anxiety/epidemiology , Anxiety/psychology , COVID-19/epidemiology , Depression/psychology , Mental Health , Pandemics , SARS-CoV-2
17.
Int J Med Robot ; 18(6): e2447, 2022 Dec.
Article in English | MEDLINE | ID: mdl-35924335

ABSTRACT

BACKGROUND: Focussed Ultrasound (FUS) combined with microbubbles (MBs) was proven a promising modality for non-invasive blood brain barrier disruption (BBBD). Herein, two devices for FUS-mediated BBBD in rodents are presented. METHODS: A two-axes robotic device was manufactured for navigating a single element FUS transducer of 1 MHz relative to the brain of rodents. A second more compact device featuring a single motorized vertical axis was also developed. Their performance was assessed in terms of motion accuracy, MRI compatibility and trans-skull BBBD in wild type mice using MBs in synergy with pulsed FUS. RESULTS: Successful BBBD was evidenced by the Evans Blue dye method, as well as by Fibronectin and Fibrinogen immunostaining. BBB permeability was enhanced when the applied acoustic intensity was increased. CONCLUSIONS: The proposed devices constitute a cost-effective and ergonomic solution for FUS-mediated BBBD in small animal models. Further experimentation is needed to examine the repeatability of results and optimise the therapeutic protocol.


Subject(s)
Blood-Brain Barrier , Robotic Surgical Procedures , Rats , Animals , Mice , Sonication/methods , Rats, Sprague-Dawley , Brain , Magnetic Resonance Imaging/methods , Models, Animal
18.
Article in English | MEDLINE | ID: mdl-35805394

ABSTRACT

Prevalence of homicide-suicides is difficult to determine in Greece due to the lack of a national tracking system. The aim of this study was to estimate the prevalence of the homicide-suicide incidents in Greece over the past 13 years, and to determine the circumstances under which they occurred, as well as the characteristics of perpetrators and victims. Two Internet search engines (google and yahoo), as well as the search engine of the major national news websites, were surveyed to identify the number of homicide-suicide cases that occurred in Greece from January 2008 to December 2020. Over the study period, 36 homicide-suicide incidents occurred in Greece, resulting in 36 suicides and 41 homicides. The above incidents reflect an annual homicide-suicide rate of 0.02 cases per 100,000 inhabitants. Most perpetrators were male (88.9%), whereas most victims were female (80.6%). Spousal-consortial cases accounted for 52.7% and familial cases for 41.7% of the total number of incidents. The use of firearms (mostly shotgun) was the most common method of homicide and suicide (58.3% and 63.9%, respectively). Women killed only their children, while men committed homicide and suicide mainly in the context of a former or current intimate partnership with the victim. Our results are in line with international homicide-suicide data. The establishment of a national surveillance system for homicides-suicides would be of paramount importance as it would facilitate accurate recording, identification of risk factors and characteristics of potential victims and perpetrators and it could ultimately be an aid to the prevention of such tragic events.


Subject(s)
Homicide , Suicide , Adolescent , Adult , Aged , Aged, 80 and over , Child , Child, Preschool , Female , Firearms , Greece/epidemiology , Homicide/statistics & numerical data , Humans , Male , Middle Aged , Prevalence , Suicide/statistics & numerical data , Young Adult
19.
Forensic Sci Med Pathol ; 18(4): 407-414, 2022 12.
Article in English | MEDLINE | ID: mdl-35771377

ABSTRACT

Falls are the second cause of accidental deaths worldwide. Falls from height are also a common method of suicide. The aim of this study is to compare the characteristics of the victims, the circumstances of the fall and the severity and distribution of the injuries reported in an autopsy case series of falls from height. This study is a retrospective analysis of consecutive autopsy cases of suicidal and accidental falls from height which were investigated in the Department of Forensic Medicine and Toxicology of the National and Kapodistrian University of Athens during the period 2011-2019. The recorded variables included demographic data of the victim, height of fall, length of hospital stay, toxicological results, the existence and location of injuries and Injury Severity Score (ISS). Victims of suicidal falls were younger (55.53 vs. 62.98, p = 0.001), they fell from higher heights (12.35 vs. 5.18 m, p < 0.001), and they sustained more severe injuries compared with victims of accidental falls (ISS 51.01 vs. 40.88, p < 0.001). Injuries in the thorax, abdomen, pelvis, upper and lower extremities were more frequently observed after a suicidal fall (93.6% vs. 67.3%, 72.1% vs. 21.4%, 72.1% vs. 27.6%, 42.9% vs. 15.3%, 45.7% vs. 13.3%, respectively-p < 0.001), probably due to the higher height of fall. Our study outlines the differences in the profile of the victims and in the severity of injuries caused by falls from height depending on the intention of the victim to fall. However, a distinctive injury pattern in victims of suicidal falls was not demonstrated.


Subject(s)
Suicidal Ideation , Wounds and Injuries , Humans , Autopsy , Retrospective Studies , Injury Severity Score
20.
Med Leg J ; 90(3): 163-165, 2022 Sep.
Article in English | MEDLINE | ID: mdl-35695246

ABSTRACT

Complicated suicides can be defined as incidents where death is caused by a subsequent trauma rather than the primary injury. Deaths which occur as a complication of the suicidal act are very rare with few reports in the literature. We present the case of a 60-year-old man who was found at his home while still alive. His body was burning and he was lying on his back impaled by shards of glass that had come from a broken glass door. An ambulance was called but the man died before arrival at hospital. The autopsy showed stab heart and lung injuries in thorax and an abdominal stab trauma which resulted in the protrusion of the small intestine. Homicide was excluded and the sequence of events was reconstructed to reveal a complicated suicide intended to result from self-immolation but which resulted in a fall against a glass door which in turn resulted in shards of glass piercing his body and a fatal stab wound to the heart.


Subject(s)
Abdominal Injuries , Heart Injuries , Suicide , Wounds, Stab , Abdominal Injuries/complications , Heart Injuries/complications , Homicide , Humans , Male , Middle Aged , Thorax , Wounds, Stab/complications